Introduction: Industrial safety systems are crucial for ensuring the well-being of workers and preventing accidents in industrial environments. These systems utilize various components and technologies to monitor and control potential hazards. In this article, we will explore the concept of an industrial safety system and provide examples of Arduino-based projects to demonstrate its implementation.

Project: The project we will create as an example is a gas leak detection system. The objective is to detect the presence of gas in a confined space and trigger an alarm to alert workers of the potential danger. The system will utilize a gas sensor, an Arduino board, and a buzzer for the alarm.

List of Components:

  1. Arduino Uno - 1x [Link to purchase: https://www.arduino.cc/en/Main/ArduinoBoardUno]

  2. Gas Sensor (MQ-2) - 1x [Link to purchase: https://www.sparkfun.com/products/9404]

  3. Buzzer - 1x [Link to purchase: https://www.sparkfun.com/products/7950]

  4. Jumper wires - as required for connections

Examples: Example 1: Gas Leak Detection System

// Gas Leak Detection System

int gasSensorPin = A0;  // Analog pin for gas sensor
int buzzerPin = 9;     // Digital pin for buzzer

void setup() {
  pinMode(buzzerPin, OUTPUT); // Set buzzer pin as output
  Serial.begin(9600);         // Initialize serial communication
}

void loop() {
  int gasLevel = analogRead(gasSensorPin);  // Read gas sensor value

  if (gasLevel > 500) {    // If gas level is above threshold
    digitalWrite(buzzerPin, HIGH);  // Turn on the buzzer
    Serial.println("Gas detected!"); // Print message to serial monitor
  } else {
    digitalWrite(buzzerPin, LOW);   // Turn off the buzzer
  }

  delay(1000);  // Delay for stability
}

Explanation:

  • The code starts by defining the pins for the gas sensor and the buzzer.
  • In the setup function, the buzzer pin is set as an output and serial communication is initialized.
  • The loop function continuously reads the gas sensor value using analogRead.
  • If the gas level exceeds a threshold of 500, the buzzer is turned on and a message is printed to the serial monitor.
  • If the gas level is below the threshold, the buzzer is turned off.
  • A delay of 1 second is added to ensure stability and prevent rapid triggering of the alarm.

Common Use Cases:

  • Industrial gas leak detection systems
  • Toxic gas monitoring in laboratories
  • Safety systems for chemical storage areas